1. Home
  2. Maintenance
  3. How do I see what the Cyclops/Sasquatch sees in real time using Vision?
  1. Home
  2. Troubleshooting
  3. How do I see what the Cyclops/Sasquatch sees in real time using Vision?
  1. Home
  2. Tools
  3. Vision
  4. How do I see what the Cyclops/Sasquatch sees in real time using Vision?
  1. Home
  2. Products
  3. Cyclops IS/ExP
  4. How do I see what the Cyclops/Sasquatch sees in real time using Vision?
  1. Home
  2. Installation
  3. How do I see what the Cyclops/Sasquatch sees in real time using Vision?
  1. Home
  2. Products
  3. Sasquatch
  4. How do I see what the Cyclops/Sasquatch sees in real time using Vision?
  1. Home
  2. Accessories
  3. Link
  4. How do I see what the Cyclops/Sasquatch sees in real time using Vision?
  1. Home
  2. Features
  3. Geomagnetic Sensing
  4. How do I see what the Cyclops/Sasquatch sees in real time using Vision?

How do I see what the Cyclops/Sasquatch sees in real time using Vision?

ETC Sensors have a unique technology embedded in them called Geomagnetic Sensing that monitors the Earth’s magnetic field in real time and then reacts to anomalies caused by ferrous metals found in plungers. By connecting Vision, we can see the changes to the magnetic field in real time.

What You Need

Before planning to monitor a sensor, you should make sure you have:

Video Tutorial

Connect Vision

Follow these steps to physically connect the sensor using a Serial connection and establish a communication session.

Set The Sensor Mode

  1. Ensure that the switch on the physical sensor is set to Program Mode (0).

2. Set the Sensor Mode in Vision by clicking Capture – Full Debug and clicking Set Mode.

3. Set the switch on the physical sensor to a non-zero position (dial setting 4 is the default operational setting).

4. Navigate to the Capture tab in Vision and click Start to begin the capture.

What am I Seeing?

Real Time Samples

The Samples (blue line) are a filtered view of the magnetic readings that the sensors uses to make decisions on. If you wish to see unfiltered readings, the Sensor Mode can be changed to Capture – Raw Samples.

ETC sensors are immune to lightning as high frequency spikes are averaged/filtered out.

Baseline

The Baseline (green line) is the long term average that is meant to represent the No Plunger condition.

The Baseline will automatically calibrate itself if the background changes.

Sensitivity Dial

The sensitivity dial on the physical sensor is read and displayed in the summary section at the top.

A higher sensitivity will detect smaller changes in the signal which is important for non-ferrous (aluminum, stainless steel, and titanium) plunger.

A lower sensitivity will ignore more interference or noise, but will also potentially miss plunger with a low ferrous content.

Threshold

The Threshold (red dots) is set based on the sensitivity dial and sets a buffer above and below the Baseline. Any change in the Samples within the buffer will be ignored.

ETC sensors avoid false trips by ignoring changes in the samples less than the Threshold. To increase noise immunity, decrease the sensitivity.

Output Switch

The current Switch status is shown in the Summary box at the top of the screen.

Plunger Arrival

The sensor monitors the Samples, Baseline, and Threshold in real time. When the Samples deviate outside the Threshold in either direction the Switch is closed.

Each time the switch is closed, it is held for a minimum of 5 seconds to ensure connected control systems are able to see the arrival. As long as the plunger continues to move, the switch will be held closed.

Special versions of firmware have been created for the Cyclops IS/ExP that increases this hold time to 30, 60, and 90 seconds to add reliability when used with polled or wireless systems.

How to Disconnect

  1. Stop the capture.
  2. Navigate to the Setup tab and change the Sensor Mode back to Normal.
  3. Disconnect the serial connection.
  4. Unplug the cable.

Ensure that the senor is put back into Normal mode. Sensors left in any of the Capture modes will transmit data which will look like a plunger arrival, tripping any attached control system.