The ALiEn2 line of controllers are designed to be ultra low powered, which does restrict the type of pressure transducer that can be powered and read. Please see the sections below for more details.
Single Pressure Transducer
A single pressure transducer is used for reading casing, line, or tubing pressure. The following table lists the required specifications.
Description | Specification |
Excitation Voltage | 5V |
Output Signal | 0.5V to 4.5V |
Supported Ranges | 100 psi – 5000 psi |
Certification | Class I Zone 0/Div 1 |
Differential Pressure
A differential pressure transducer is used to measure the pressure differential across an orifice plate, which is required if you are using the built in flow calculation. The following table lists the required specifications.
Description | Specification |
Excitation Voltage | 5V |
Output Signal | 0.8V to 3.2V |
Supported Ranges | 100 psi – 5000 psi |
Certification | Class I Zone 0/Div 1 |